    MTT assay on 96 well plate

    Adita Ayu Permanasari

    Published: 2022-11-03 DOI: 10.17504/protocols.io.6qpvr4x5pgmk/v1
    AI 解读
    浏览 1339

    Abstract

    MTT assay to measure viability cells

    Steps

    1.

    Prepare sample in DMSO

    2.

    Observe cell on the plate, make a note about cells condition

    3.

    Experiment by make a serial dilution sample in U-Type, suspend 40 times

    4.

    Remove old medium from cells

    5.

    Put 100 μl/well sample and DMSO, incubate 48 h, 37 oC

    6.

    Observe condition cells after 48 h incubation

    7.

    Checked toxicity under microscope, take photo if there are morphology changing

    8.

    Prepare MTT 10%

    9.

    Remove medium from 96 well plate

    10.

    Put 150 μl/well by multichannel pipet, incubate 4 h, 37 oC

    11.

    Remove MTT solution from well plate

    12.

    Put 100 μl/well DMSO 100% for dissolve

    13.

    Check absorbance at 560 nm and 750 nm , shaker 0.5 min before read absorbance